<?xml version="1.0" encoding="utf-8"?>
<rss version="2.0">
    <channel>
        <title><![CDATA[Emant RSS: Low Cost USB, Bluetooth Wireless Data Acquisition]]></title>
        <link><![CDATA[http://www.emant.com]]></link>
        <copyright><![CDATA[(c) 2007-2009, Emant Pte Ltd]]></copyright>
        <language>en-us</language>
        <webMaster><![CDATA[webmaster@emant.com]]></webMaster>
        <category><![CDATA[Data Acquisition Hardware and Software]]></category>
        <description><![CDATA[Emant Syndicated News (RSS)]]></description>
        <image>
            <url>http://www.emant.com/image/logo.png</url>
            <title>Emant RSS Feeds</title>
            <link>mailto:info@emant.com?subject=RSS%20Feed%20Question</link>
        </image>

		<item>
            <title><![CDATA[Measure Solar Panel Current Voltage Power]]></title>
            <link><![CDATA[http://www.emant.com/733010.page]]></link>
            <description><![CDATA[
				How to monitor a solar panel output voltage and current. 
				The Voc is 22V and its short circuit current is 0.6A.
		]]></description>
            <pubDate><![CDATA[Mon, 12 Apr 2010 12:00:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application]]></category>
        </item>
		
		<item>
            <title><![CDATA[Write Sensor Data to Cloud]]></title>
            <link><![CDATA[http://www.sensor-cloud.com]]></link>
            <description><![CDATA[
				Write Sensor Data to the Cloud. Restrict sharing to only Friends Worldwide
		]]></description>
            <pubDate><![CDATA[Mon, 1 Mar 2010 12:00:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application]]></category>
        </item>

        <item>
            <title><![CDATA[24V DIO Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/24VDIO.page]]></link>
            <description><![CDATA[
The 24V DIO Application Adaptor allows the EMANT300 USB Data Acquisition Module or the EMANT380 Bluetooth Data Acquisition Module to connect to Digital Signals up
	to 24V. It allows for quick connection to industrial digital signals which often are greater than 5V.
]]></description>
            <pubDate><![CDATA[Mon, 2 Nov 2009 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Adaptor]]></category>
        </item>

        <item>
            <title><![CDATA[Windows Mobile Visual Basic and DAQ Tutorial]]></title>
            <link><![CDATA[http://www.emant.com/windows-mobile-vb2005-01.page]]></link>
            <description><![CDATA[
Visual Basic Compact Framework with EMANT380. Getting Started on Windows Mobile with Bluetooth DAQ.
]]></description>
            <pubDate><![CDATA[Fri, 17 Jul 2009 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Pinch Meter Assembly]]></title>
            <link><![CDATA[http://www.emant.com/90110.page]]></link>
            <description><![CDATA[
Measures Pinch Strength. Used to demonstrate a typical strain gage application.
]]></description>
            <pubDate><![CDATA[Thu, 16 Jul 2009 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Accessory]]></category>
        </item>

        <item>
            <title><![CDATA[Accelerometer Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/90090.page]]></link>
            <description><![CDATA[
Connects the MMA7260QT &plusmn;1.5g - 6g Three Axis Low-g Micromachined Accelerometer to the EMANT380 Bluetooth DAQ.
]]></description>
            <pubDate><![CDATA[Fri, 19 Jun 2009 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Adaptor]]></category>
        </item>

        <item>
            <title><![CDATA[Compass Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/90100.page]]></link>
            <description><![CDATA[
Connects the HMC1052 which measures direction and magnitude of Earth's magnetic fields from 120 micro-gauss to 6 gauss to the EMANT380 Bluetooth DAQ.
]]></description>
            <pubDate><![CDATA[Fri, 19 Jun 2009 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Adaptor]]></category>
        </item>

        <item>
            <title><![CDATA[Bridge Completion Network]]></title>
            <link><![CDATA[http://www.emant.com/90080.page]]></link>
            <description><![CDATA[
The Bridge Completion Network is used to complete quarter and half bridge strain gauge circuits.
]]></description>
            <pubDate><![CDATA[Mon, 13 Apr 2009 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Accessory]]></category>
        </item>

        <item>
            <title><![CDATA[Bridge Sensor Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/697005.page]]></link>
            <description><![CDATA[
The Bridge Sensor Application Adaptor is used to connect bridge sensors like strain gauge, force sensor, pressure sensor, load cells in PC or Smartphone based Data Acquisition Systems.
]]></description>
            <pubDate><![CDATA[Mon, 2 Mar 2009 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Adaptor]]></category>
        </item>


        <item>
            <title><![CDATA[Symbian S60, Python and DAQ Tutorial]]></title>
            <link><![CDATA[http://www.emant.com/100101.page]]></link>
            <description><![CDATA[
Python S60 with EMANT380. Beta Python Driver for the EMANT380 Bluetooth DAQ for the Symbian S60 3rd Edition.
]]></description>
            <pubDate><![CDATA[Tues, 24 Feb 2009 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Pressure Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/698007.page]]></link>
            <description><![CDATA[
Used with the EMANT300 USB Data Acquisition Module or the EMANT380 Bluetooth Data Acquisition Module, they form a very low cost PC or Smartphone based Manometer. It is ideal for use in hands-on teaching laboratories and projects involving pressure measurements.
]]></description>
            <pubDate><![CDATA[Mon, 23 Feb 2009 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Adaptor]]></category>
        </item>

        <item>
            <title><![CDATA[EMANT380 Wireless Bluetooth DAQ]]></title>
            <link><![CDATA[http://www.emant.com/251006.page]]></link>
            <description><![CDATA[
The EMANT380 is a low-cost and compact 24 bit wireless (DAQ) data acquisition module developed for learning purposes. As a wireless DAQ module, it is useful in appplications where isolation is important. It can be used readily with a desktop personal computer for data acquisition and control. When connected to a notebook or smartphone, portability is achieved.
]]></description>
            <pubDate><![CDATA[Mon, 20 Oct 2008 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Module]]></category>
        </item>

        <item>
            <title><![CDATA[Screw Terminals Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/90020.page]]></link>
            <description><![CDATA[The Screw Terminals Application Adaptor connects the pin out of the DB25 connector of the EMANT300 Low Cost USB Data Acquisition Module to screw terminals.
]]></description>
            <pubDate><![CDATA[Mon, 26 Nov 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Adaptor]]></category>
        </item>

        <item>
            <title><![CDATA[Prototype Board Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/90000.page]]></link>
            <description><![CDATA[The Prototype Board Application Adaptor connects the pin out of the DB25 connector of the EMANT300 Low Cost USB Data Acquisition Module to your custom application circuit.
]]></description>
            <pubDate><![CDATA[Mon, 26 Nov 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Adaptor]]></category>
        </item>

        <item>
            <title><![CDATA[Breadboard Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/90010.page]]></link>
            <description><![CDATA[The Breadboard Application Adaptor connects the pin out of the DB25 connector of the EMANT300 Low Cost USB Data Acquisition Module to a breadboard.
]]></description>
            <pubDate><![CDATA[Mon, 26 Nov 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Adaptor]]></category>
        </item>

        <item>
            <title><![CDATA[Stepper Motor Control]]></title>
            <link><![CDATA[http://www.emant.com/80140.page]]></link>
            <description><![CDATA[Control a stepper motor using the EMANT300 and the ULN2003 darlington array.
]]></description>
            <pubDate><![CDATA[Wed, 24 Oct 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Measure Depth using Hydrostatic Pressure]]></title>
            <link><![CDATA[http://www.emant.com/80120.page]]></link>
            <description><![CDATA[One way to measure depth using hydrostatic pressure is to use the EMANT300 USB DAQ with the Pressure Application Adaptor and some aquarium airline tubing. This is because the gauge pressure due to water alone at a given depth is proportional to the depth.
]]></description>
            <pubDate><![CDATA[Wed, 10 Oct 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[DC Fan Speed Control]]></title>
            <link><![CDATA[http://www.emant.com/80110.page]]></link>
            <description><![CDATA[Using Pulse-width modulation (PWM), the fan's power supply is turned on and off at a fixed frequency. By changing the duty-cycle, we control the speed of the fan. The EMANT300 USB DAQ uses the ULN2003 to drive the DC Fan.
]]></description>
            <pubDate><![CDATA[Wed, 26 Sep 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Hand Dynamometer]]></title>
            <link><![CDATA[http://www.emant.com/80100.page]]></link>
            <description><![CDATA[A hand dynamometer is used to measure grip strength. This application note illustrates the use of the strain gauge in the construction of a hand dynanometer.
]]></description>
            <pubDate><![CDATA[Wed, 5 Sep 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Switching 3A 230Vac Loads]]></title>
            <link><![CDATA[http://www.emant.com/80050.page]]></link>
            <description><![CDATA[This app note describes how the EMANT300 USB DAQ can switch 3A 250Vac loads
]]></description>
            <pubDate><![CDATA[Wed, 15 Aug 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Matlab & EMANT300]]></title>
            <link><![CDATA[http://www.emant.com/80002.page]]></link>
            <description><![CDATA[This app note for experienced Matlab users shows how to interface Matlab to the EMANT300 USB DAQ
]]></description>
            <pubDate><![CDATA[Wed, 1 Aug 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Measure Distance using the Ultrasonic Sensor]]></title>
            <link><![CDATA[http://www.emant.com/index.php?tid=100011]]></link>
            <description><![CDATA[Measure Distance using the Ultrasonic Sensor with the EMANT300 USB DAQ
]]></description>
            <pubDate><![CDATA[Mon, 4 Jun 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>
        <item>
            <title><![CDATA[Measure Center of Pressure]]></title>
            <link><![CDATA[http://www.emant.com/index.php?tid=100001]]></link>
            <description><![CDATA[Measure the center of pressure by converting a low cost personal weighing scale and using the EMANT300 USB DAQ and strain application adaptor
]]></description>
            <pubDate><![CDATA[Tues, 29 May 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>
        <item>
            <title><![CDATA[Counter]]></title>
            <link><![CDATA[http://www.emant.com/index.php?tid=148000]]></link>
            <description><![CDATA[Counters basically count the number of pulses at its input. The EMANT300 DAQ module has one 16 bit counter input. Please note that since the counter shares the same clock as the PWM function, you can only use either the PWM function or Counter function.
]]></description>
            <pubDate><![CDATA[Tues, 12 Mar 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>
        <item>
            <title><![CDATA[Skype and EMANT300]]></title>
            <link><![CDATA[http://www.emant.com/index.php?tid=148010]]></link>
            <description><![CDATA[Skype allows you to make free calls to anyone else on Skype, anywhere in the world. It also includes messaging. Thus it is a good platform for remote measurement and control. This app note explains how to use Skype to measure light intensity and turn on/off an LED using the EMANT300 with the light application adaptor
]]></description>
            <pubDate><![CDATA[Tues, 13 Mar 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>
    </channel>
</rss>