<?xml version="1.0" encoding="utf-8"?>
<rss version="2.0">
    <channel>
        <title><![CDATA[Emant RSS: Low Cost USB Data Acquisition]]></title>
        <link><![CDATA[http://www.emant.com]]></link>
        <copyright><![CDATA[(c) 2007, Emant Pte Ltd]]></copyright>
        <language>en-us</language>
        <webMaster><![CDATA[webmaster@emant.com]]></webMaster>
        <category><![CDATA[Data Acquisition Hardware and Software]]></category>
        <description><![CDATA[Emant Syndicated News (RSS)]]></description>
        <image>
            <url>http://www.emant.com/image/logo.png</url>
            <title>Emant RSS Feeds</title>
            <link>mailto:info@emant.com?subject=RSS%20Feed%20Question</link>
        </image>

        <item>
            <title><![CDATA[Screw Terminals Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/90020.page]]></link>
            <description><![CDATA[The Screw Terminals Application Adaptor connects the pin out of the DB25 connector of the EMANT300 Low Cost USB Data Acquisition Module to screw terminals.
]]></description>
            <pubDate><![CDATA[Mon, 26 Nov 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Accessory]]></category>
        </item>

        <item>
            <title><![CDATA[Prototype Board Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/90000.page]]></link>
            <description><![CDATA[The Prototype Board Application Adaptor connects the pin out of the DB25 connector of the EMANT300 Low Cost USB Data Acquisition Module to your custom application circuit.
]]></description>
            <pubDate><![CDATA[Mon, 26 Nov 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Accessory]]></category>
        </item>

        <item>
            <title><![CDATA[Breadboard Application Adaptor]]></title>
            <link><![CDATA[http://www.emant.com/90010.page]]></link>
            <description><![CDATA[The Breadboard Application Adaptor connects the pin out of the DB25 connector of the EMANT300 Low Cost USB Data Acquisition Module to a breadboard.
]]></description>
            <pubDate><![CDATA[Mon, 26 Nov 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Accessory]]></category>
        </item>

        <item>
            <title><![CDATA[Stepper Motor Control]]></title>
            <link><![CDATA[http://www.emant.com/80140.page]]></link>
            <description><![CDATA[Control a stepper motor using the EMANT300 and the ULN2003 darlington array.
]]></description>
            <pubDate><![CDATA[Wed, 24 Oct 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Measure Depth using Hydrostatic Pressure]]></title>
            <link><![CDATA[http://www.emant.com/80120.page]]></link>
            <description><![CDATA[One way to measure depth using hydrostatic pressure is to use the EMANT300 USB DAQ with the Pressure Application Adaptor and some aquarium airline tubing. This is because the gauge pressure due to water alone at a given depth is proportional to the depth.
]]></description>
            <pubDate><![CDATA[Wed, 10 Oct 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[DC Fan Speed Control]]></title>
            <link><![CDATA[http://www.emant.com/80110.page]]></link>
            <description><![CDATA[Using Pulse-width modulation (PWM), the fan's power supply is turned on and off at a fixed frequency. By changing the duty-cycle, we control the speed of the fan. The EMANT300 USB DAQ uses the ULN2003 to drive the DC Fan.
]]></description>
            <pubDate><![CDATA[Wed, 26 Sep 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Hand Dynamometer]]></title>
            <link><![CDATA[http://www.emant.com/80100.page]]></link>
            <description><![CDATA[A hand dynamometer is used to measure grip strength. This application note illustrates the use of the strain gauge in the construction of a hand dynanometer.
]]></description>
            <pubDate><![CDATA[Wed, 5 Sep 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Switching 3A 230Vac Loads]]></title>
            <link><![CDATA[http://www.emant.com/80050.page]]></link>
            <description><![CDATA[This app note describes how the EMANT300 USB DAQ can switch 3A 250Vac loads
]]></description>
            <pubDate><![CDATA[Wed, 15 Aug 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Matlab & EMANT300]]></title>
            <link><![CDATA[http://www.emant.com/80002.page]]></link>
            <description><![CDATA[This app note for experienced Matlab users shows how to interface Matlab to the EMANT300 USB DAQ
]]></description>
            <pubDate><![CDATA[Wed, 1 Aug 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>

        <item>
            <title><![CDATA[Measure Distance using the Ultrasonic Sensor]]></title>
            <link><![CDATA[http://www.emant.com/index.php?tid=100011]]></link>
            <description><![CDATA[Measure Distance using the Ultrasonic Sensor with the EMANT300 USB DAQ
]]></description>
            <pubDate><![CDATA[Mon, 4 Jun 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>
        <item>
            <title><![CDATA[Measure Center of Pressure]]></title>
            <link><![CDATA[http://www.emant.com/index.php?tid=100001]]></link>
            <description><![CDATA[Measure the center of pressure by converting a low cost personal weighing scale and using the EMANT300 USB DAQ and strain application adaptor
]]></description>
            <pubDate><![CDATA[Tues, 29 May 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>
        <item>
            <title><![CDATA[Counter]]></title>
            <link><![CDATA[http://www.emant.com/index.php?tid=148000]]></link>
            <description><![CDATA[Counters basically count the number of pulses at its input. The EMANT300 DAQ module has one 16 bit counter input. Please note that since the counter shares the same clock as the PWM function, you can only use either the PWM function or Counter function.
]]></description>
            <pubDate><![CDATA[Tues, 12 Mar 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>
        <item>
            <title><![CDATA[Skype and EMANT300]]></title>
            <link><![CDATA[http://www.emant.com/index.php?tid=148010]]></link>
            <description><![CDATA[Skype allows you to make free calls to anyone else on Skype, anywhere in the world. It also includes messaging. Thus it is a good platform for remote measurement and control. This app note explains how to use Skype to measure light intensity and turn on/off an LED using the EMANT300 with the light application adaptor
]]></description>
            <pubDate><![CDATA[Tues, 13 Mar 2007 12:10:00 PST]]></pubDate>
            <category><![CDATA[Data Acquisition Application Note]]></category>
        </item>
    </channel>